Service Tools | |
---|---|
Part Number | Part |
JERD2129 | Caterpillar Electronic Technician (Cat ET) |
275-5120 | Communication Adapter Gp for use with Cat ET |
257-9140 | Digital Multimeter |
8T-3224 | Needle Tip |
7X-1710 | Multimeter Probe |
300-8648 | Insulation Tester Gp |
8T-8726 | Adapter Cable As |
208-0059 | Adapter Cable As |
8T-5319 | Connector Tool Group |
9U-7246 | Connector Repair Kit |
140-9944 | Terminal Repair Kit |
4C-3406 | Connector Repair Kit |
177-2330 | Digital Battery Analyzer |
4C-4911 | Battery Load Tester |
Illustration 1 | g02006493 |
Connections for the Communication Adapter II and the Caterpillar Electronic Technician (Cat ET) The components that are needed in order to use the Communication Adapter II and Cat ET in order to determine diagnostic codes are listed: (1) Cable (2) 275-5120 Communication Adapter Gp (3) Service diagnostic cable. (4) Current version of Cat ET software and Laptop computer |
Reference: Refer to the Special Publication, NEHS0758, "Communications Adapter II User's Manual ".
The following materials are required in order to use Cat ET: Special Publication, JERD2124, "ET Single Use Program License", Special Publication, JEHP1026, "Information and Requirements Sheet", 7X-1425 Data Link Cable and the Data Subscription and Special Publication, JERD2142, "Data Subscription".
Note: The Special Publication, JEHP1026, "Information and Requirements Sheet" is a list of the required hardware and the features of the Cat ET.
Cat ET is not required in order to read diagnostic codes or to clear diagnostic codes. Cat ET can provide more information about the equipment faster than other methods of reading the codes. Cat ET will display information on the history of a diagnostic code and the parameter status of diagnostic codes. These features allow Cat ET to be a useful tool for troubleshooting.
Cat ET is used to communicate to Electronic Control Modules (ECM) via the service port.
Note: The service port is located on the right side of the seat for the operator and to the rear of the fuse panel.
For instructions on servicing Sure Seal connectors, refer to Special Instruction, SMHS7531. For instructions on servicing Deutsch connectors, refer to Special Instruction, SEHS9615.
The 7X-1710 Multimeter Probes are used to measure the voltage at the connectors without disconnecting the connectors. The probe ends are pushed into the back of the connector along the wire.
Note: Certain machine wiring harnesses on the D7E Track-Type Tractor are sealed. The 7X-1710 Multimeter Probes can not be used on these harnesses. The troubleshooting procedures that are listed in this manual will provide instructions for the probes when the probes can be used.
The 151-6320 Removal Tool is used to remove a socket or a pin from the connector body. The 8T-8726 Adapter Cable has a breakout with 3 pins. The adapter cable is used for measurements in the sensor circuits.