Starting Motor - Delco 50-MT Caterpillar


Starting Motor Does Not Turn or Turns Slowly

Usage:

769C 01X
System Operation Description:

The possible causes of this failure are listed below:

  • The battery is discharged or the battery is faulty.

  • The cables to the starter have failed.

  • The ignition switch has failed.

  • The engine is locked.

  • The starting motor solenoid has failed.

  • The starting motor has an internal problem.

The following tables will be referenced in troubleshooting the starting motor.

Table 1
TYPICAL SYSTEM VOLTAGE DURING CRANKING AT VARIOUS AMBIENT TEMPERATURES 
Temperature  24 Volt System  32 Volt System  64 Volt System 
−23 °C (−9.4 °F) to −7 °C (19.4 °F)  12 to 16 Volts  16 to 21 Volts  NA 
−7 °C (19.4 °F) to 10 °C (50 °F)  14 to 18 Volts  18 to 24 Volts  NA 
10 °C (50 °F) to 27 °C (80 °F)  16 to 20 Volts  21 to 27 Volts  NA 

Table 2
MAXIMUM ACCEPTABLE VOLTAGE DROPS DURING CRANKING 
Circuit  24 Volt System  32 Volt System  64 Volt System 
Battery negative post to the negative terminal on the starting motor   1.4 Volts  1.9 Volts  3.8 Volts 
Drop across disconnect switch  1.0 Volts  1.3 Volts  2.6 Volts 
Battery positive post to the positive terminal on the solenoid   1.0 Volts  1.3 Volts  2.6 Volts 
Battery terminal of the solenoid to the motor terminal of the solenoid   0.8 Volts  0.4 Volts  0.4 Volts 

Test Step 1. CHECK THE BATTERY VOLTAGE

  1. Attempt to crank the engine. Measure the battery voltage with the digital multimeter. Measure the voltage at the battery posts. Do not measure the voltage at the terminal of the battery cable.

  2. Compare the voltage to table 1.

Expected Result:

The battery voltage is equal to or greater than the voltage in table 1.

Results:

  • OK - Battery voltage is correct. Go to test step 2.

  • NOT OK - Battery voltage is too low.

    Repair: Check the charging system. See Special Instruction, REHS 0354, "Charging System Troubleshooting".

    STOP

Test Step 2. TEST THE DISCONNECT SWITCH

  1. Ensure that the disconnect switch is in the CLOSED position.

  2. Measure the resistance across the terminals of the disconnect switch.

Expected Result:

The resistance should be less than 5 ohms.

Results:

  • OK - The resistance is less than 5 ohms. The disconnect switch is correct. Proceed to test step 3.

  • NOT OK - The resistance is greater than 5 ohms. The disconnect switch is not correct.

    Repair: Replace the battery disconnect switch.

    STOP

Test Step 3. TEST CABLES FROM THE BATTERY TO THE STARTING MOTOR

  1. Visually inspect the battery cable terminals for the following conditions:

    • Loose connections

    • Corroded cables

Expected Result:

The cables should be clean and the cables should be tight.

Results:

  • OK - Battery cables are in good condition. Proceed to test step 4.

  • NOT OK - Battery cables are incorrect.

    Repair: Clean the terminals or replace the terminals. Tighten the terminals.

    STOP

Test Step 4. TEST CABLES FROM THE BATTERY TO THE STARTING MOTOR FOR VOLTAGE DROP

  1. Attempt to crank the engine. Measure the voltage from "Mtr" terminal to ground.

Expected Result:

The battery voltage is less than the voltage in table 2.

Results:

  • OK - The voltage drop is less than the specified voltage drop. Proceed to test step 5.

  • NOT OK - The voltage drop is greater than the specified voltage drop.

    Repair: Repair the cables or replace the cables. Repeat the voltage measurement. If the voltage remains low, measure the voltage drop across each component that is listed in table 2. Replace all components that are out of specification.

    STOP

Test Step 5. CHECK ENGINE ROTATION

  1. Remove the starter from the engine.

  2. Turn the engine by hand.

Expected Result:

The engine turns with normal effort.

Results:

  • YES - The engine turns with normal effort. Proceed to test step 6.

  • NO - The engine turns with more than normal effort. The engine needs to be serviced.

    Repair: Repair the engine. Refer to the Disassembly and Assembly manual for the engine.

    STOP

Test Step 6. TEST THE START RELAY

  1. Locate the start relay for the starter.

  2. Attempt to crank the engine. Measure the resistance across the start relay.

Expected Result:

The resistance should be less than 5 ohms.

Results:

  • OK - The resistance is less than 5 ohms. The start relay is correct. Proceed to test step 7.

  • NOT OK - The resistance is greater than 5 ohms. The start relay has failed.

    Repair: Replace the start relay.

    STOP

Test Step 7. TEST THE STARTING MOTOR SOLENOID

  1. Perform the starting motor solenoid test. See Testing and Adjusting, "Starting Motor Solenoid - Test".

Expected Result:

The solenoid is correct.

Results:

  • OK - The solenoid is correct. Go to test step 8.

  • NOT OK - The solenoid is incorrect.

    Repair: Replace the solenoid.

    STOP

Test Step 8. TEST THE INTERNAL COMPONENTS OF THE STARTING MOTOR

  1. Check starting motor brushes. See Testing and Adjusting, "Brush and Brush Holder - Check".

Expected Result:

The brushes of the starting motor are correct.

Results:

  • OK - The brushes of the starting motor are correct.

    Repair: Perform the component tests for the starting motor. See the proper test in the Testing and Adjusting section.

    STOP

  • NOT OK - The brushes are incorrect.

    Repair: Replace brushes or repair brushes. Repair the brush holder or replace the brush holder.

    STOP

Caterpillar Information System:

Starting Motor - Delco 50-MT Pinion Clearance - Adjust
Starting Motor - Delco 50-MT No Load - Test
Starting Motor - Delco 50-MT Pinion Drive - Check
Starting Motor - Delco 50-MT Brush and Brush Holder - Check
345D, 349D and 349D2 Excavator Machine System Specifications Stick Cylinder Lines - Stick Lowering Control
Starting Motor - Delco 50-MT Armature - Test
Starting Motor - Delco 50-MT Field Winding - Test
Starting Motor - Delco 50-MT Starting Motor Solenoid - Test
Starting Motor - Delco 50-MT Pinion Continues to Engage after Engine Starts
Starting Motor - Delco 50-MT Starting Motor Continues to Operate after Start Switch Has Been Released
Starting Motor - Delco 50-MT Engine Does Not Crank with Starting Motor On and Pinion Engaging Ring Gear
Starting Motor - Delco 50-MT Pinion Does Not Engage Ring Gear
C9 Agricultural Engine for Challenger Tractors Engine Shutdown Is Intermittent
Starting Motor - Delco 50-MT General Information
Starting Motor - Delco 50-MT Starting Motor - Disassemble
Starting Motor - Delco 50-MT Starting Motor - Assemble
3176C, 3406E and 3456 Industrial Engines Engine Stalls at Low RPM
C4.4 (Mech) Industrial Engine Crankcase Breather (Canister) - Replace
C3.4 IND Industrial Engine Engine Valve Lash - Inspect/Adjust
C4.4 and C6.6 Engines for Caterpillar Built Machines Fuel Rail Pump Solenoid - Test
C3.4 IND Industrial Engine Reference Material
C9 Agricultural Engine for Challenger Tractors Engine Top Speed Is Not Obtained
C3.4 IND Industrial Engine Maintenance Interval Schedule
Starting Motor - Delco 50-MT Normal Operation
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.