Starting Motor - Delco 50-MT Caterpillar


Field Winding - Test

Usage:

769C 01X

Table 1
Tools Needed 
6V-7070 Digital Multimeter 

Field Winding Ground - Test



Illustration 1g00715885
Field winding ground test
(1) Field winding leads
(2) "Mtr" Motor terminal

Note: A visual check of the field windings should be done first. Check for wear and damage. Check all of the connections for imperfections in the solder joints.

  1. Place the multimeter in the "20M Ω" range. Touch the multimeter leads between each field winding lead (1) and the case of the starting motor.

  2. Touch the multimeter leads between the "Mtr" motor terminal (2) and the case of the starting motor.

  3. Each reading should be greater than 100,000 Ohms. The multimeter should read "0.10" or a value that is greater.

  4. If the meter reading is less than 100,000 Ohms, the field winding is grounded. The case of the starting motor and field windings must be replaced.

Field Winding Continuity - Test



Illustration 2g00715887
Field winding continuity test
(1) Field winding leads
(2) "Mtr" Motor terminal

Note: A visual check of the field windings should be done first. Check for wear and damage. Check all of the connections for imperfections in the solder joints.

  1. Place the multimeter on the "200 Ω" range. Touch the meter leads between the field winding leads (1).

  2. Touch the meter leads between each field winding lead (1) and motor terminal lead (2).

  3. Each reading should be "00.0" to "00.1" Ohms.

  4. If the meter reading is higher than the meter reading in Step 3, there is an open in the field winding. The case of the starting motor and the field windings must be replaced.

Caterpillar Information System:

Starting Motor - Delco 50-MT Starting Motor Solenoid - Test
Starting Motor - Delco 50-MT Pinion Continues to Engage after Engine Starts
Starting Motor - Delco 50-MT Starting Motor Continues to Operate after Start Switch Has Been Released
Starting Motor - Delco 50-MT Engine Does Not Crank with Starting Motor On and Pinion Engaging Ring Gear
Starting Motor - Delco 50-MT Pinion Does Not Engage Ring Gear
Starting Motor - Delco 50-MT Service Tools
Starting Motor - Delco 50-MT General Information
C9 On-highway Engine Cylinder Block Cover - Remove and Install
Starting Motor - Delco 50-MT General Information
Starting Motor - Delco 50-MT Component Description
C32 Marine Engines Fuel Priming Pump - Remove and Install
C9 Agricultural Engine for Challenger Tractors Engine Cranks but Does Not Start
Starting Motor - Delco 50-MT Armature - Test
345D, 349D and 349D2 Excavator Machine System Specifications Stick Cylinder Lines - Stick Lowering Control
Starting Motor - Delco 50-MT Brush and Brush Holder - Check
Starting Motor - Delco 50-MT Pinion Drive - Check
Starting Motor - Delco 50-MT No Load - Test
Starting Motor - Delco 50-MT Pinion Clearance - Adjust
Starting Motor - Delco 50-MT Starting Motor Does Not Turn or Turns Slowly
C9 Agricultural Engine for Challenger Tractors Engine Shutdown Is Intermittent
Starting Motor - Delco 50-MT General Information
Starting Motor - Delco 50-MT Starting Motor - Disassemble
Starting Motor - Delco 50-MT Starting Motor - Assemble
3176C, 3406E and 3456 Industrial Engines Engine Stalls at Low RPM
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.