Illustration 1 | g01947782 |
Typical example |
(1) Torque for the bolts ... 55 ± 10 N·m (41 ± 7 lb ft)
(2) Torque for the magnetic plug ... 73.5 ± 3.5 N·m (54.2 ± 2.6 lb ft)
(3) Torque for two O-ring plugs ... 50 ± 5 N·m (37 ± 4 lb ft)
(4) Torque for two connector assemblies ... 25.25 ± 1.25 N·m (223.48 ± 11.06 lb in)
(5) Torque for the connections on the tube assembly ... 42 ± 2 N·m (31 ± 1 lb ft)
(6) Torque for the O-ring plug ... 110 ± 5 N·m (81 ± 4 lb ft)
(7) Lubricate the bore of the O-ring seal lightly with the lubricant that is being sealed.
Note: Lubricate the threads of taperlock stud (8) with 4C-5599 Anti-Seize Compound . Assemble the taperlock stud with the letter "X" outward.
(8) Torque for three taperlock studs ... 17 ± 5 N·m (150 ± 44 lb in)
(9) Torque for five bolts ... 28 ± 7 N·m (248 ± 62 lb in)
(10) Torque for the plug assembly ... 8 ± 1 N·m (71 ± 9 lb in)
(C) Height to the top of the taperlock stud after installation ... 31.0 ± 0.5 mm (1.22 ± 0.02 inch)