- Track-Type Tractor:
- D11R (S/N: AAF1-UP; 7PZ1-UP)
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.
Problem
Illustration 1 | g01290408 |
The "B+" terminal on the front of the lower starter solenoid (1) may be loose or separated from the solenoid. The cause of this failure is currently under investigation.
Solution
In warm weather, a D11R may start with only one functional starter. It may not be apparent that one starter has a failed or loose connection.If inspection reveals a loose or separated terminal replace the solenoid with the current parts until a permanent solution is determined. This will avoid any dead shorts or arcing of electrical components that might result in damage to surrounding components.