UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Caterpillar


Flywheel Transformer

Information for equipment:


ELECTRICAL AND STARTING SYSTEM
TRANSFORMER GP

Zig Zag Transformer (SMS Bypass Cabinet) UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Fan Transformer UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Transformer (T1 to T3) UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Current Transformers (Primary, Secondary) UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Zig Zag Transformer (MMS System Cabinet) UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Flywheel Transformer UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies


Description




Illustration 1g01277831

(1) Transformer "T2"

(1) Transformer "T1"

Transformer "T1" (2) and Transformer "T2" (1) are multitap transformers that provide AC power to the Power Distribution PWA. Transformer "T1" (2) is supplied from the input of the UPS. Transformer "T2" (1) is supplied from the protected output of the UPS. The transformers are installed on the left panel of the cabinet. Refer to Illustration 1 for the locations of the transformer.

Removal Procedure

Refer to Systems Operation, Testing and Adjusting, RENR9988, "Internal Component Preremoval Steps (Flywheel Cabinet)" in order to shut down the system and gain access to internal components.

  1. Remove the two screws that attach the thermistor to the terminal block.

  1. Remove each thermistor from the terminal block.

    Note: One screw is attached to the "H1" terminal connector and one screw is attached to the "COM" or "H2" terminal connector.

Installation Procedure




    Illustration 2g01277850

    Wiring for the Transformer

  1. Place one lead of the thermistor into the "H1" connector. Place one lead into the "COM" or "H2" connector. Refer to Illustration 2.

  1. Tighten the two screws in order to firmly attach the thermistor.

Table 1
Specifications for the Transformer    
    Input (V)     Output (V)     Wire Gauge (AWG)    
T1     380, 400, 415, 480     190, 230     10-22    
T2     380, 400, 415, 480     190, 230     10-22    

Table 2
Specifications for the Thermistor    
    Size     Ohm    
T1     32 mm     20    
T2     32 mm     20    

Caterpillar Information System:

UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Contactor (K1, K2)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies 24V Power Supply (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Static Switch
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Fan Monitor PWA (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Fan (Flywheel Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys General Information (Controls Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Line Inductor
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Transformer (T5)
2006/08/14 Caterpillar Factory Commissioning Services {1000, 4450, 7000, 7002}
3500 Engines Exhaust Manifold
3500 Engines Exhaust Manifold
Power Module Aftercooler Water Line Rework{1063, 1071} Power Module Aftercooler Water Line Rework{1063, 1071}
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies DC Interface PWA
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Field Coil Driver
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Internal Component Preremoval Steps (Controls Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Inverter Assembly
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Fuse (Controls Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Utility Inverter Assembly
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies SKiiP Interface PWA
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Assembly
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Rotor Position Sensor Assembly
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Vacuum Gauge
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Interface PWA
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Vacuum Pump
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.