The "Full Load Setting" (FLS) represents an adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate.
A new ECM requires this parameter to be programmed. "FLS" will be displayed beneath the 630-2 code until the FLS is programmed. Factory passwords are not required in order to program the FLS into a new ECM.
Factory passwords are required to change the FLS after an FLS has been programmed.
"Full Torque Setting" (FTS) is similar to "Full Load Setting".
A new ECM requires this parameter to be programmed. "FTS" will be displayed beneath the 630-2 code until the FTS is programmed. Factory passwords are not required in order to program the FTS into a new ECM.
Factory passwords are required to change the FTS after an FTS has been programmed.
Every flash file contains a personality module code. The personality module code indicates the horsepower family and the emission certification of the flash file.
When a flash file is loaded into a new ECM, the ECM stores the personality module code into memory. When a different flash file is loaded into an ECM, the ECM compares the new personality module code with the personality module code that is stored in memory. The ECM causes the following conditions to occur if the personality module codes do not match:
- The engine speed is limited to low idle.
- A 630-2 code is activated. "Personality Module Code" is displayed beneath the code.
Perform one of the following actions in order to correct the condition:
- Obtain factory passwords. Factory passwords will allow you to change the personality module code.
- Load the correct flash file into the ECM.
"CAN Communication Protocol Write Security"
This parameter is for factory use only.
"CAN Communication Protocol Read Security"
This parameter is for factory use only.