UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Caterpillar


Door Pull and Retaining Ring

Usage:

UPS 250 APZ

Information for equipment:


ENCLOSURES, GUARDS AND BASES
ENCLOSURE GP

General Information (Cabinet Hardware) UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Door UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Door Pull and Retaining Ring UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Door Latch UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies
Front Screen and Air Filter UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies


Description




Illustration 1g01272741

Exterior View of the Cabinet Door and Door Pull

(1) Door

(2) Door Pull




Illustration 2g01272776

Interior View of Door Pull and Ring

(3) Door Latch

(4) "C shaped" Retaining Ring

A door pull (2) is located in the UPS System. See Illustration 1 for a representative location. The door pull (2) is a circular black plastic cylinder that is a fitted assembly through a hole in the door (1). The door pull (2) is held in place by a "C shaped" retaining ring (4) .

Removal Procedure

  1. Open the cabinet door (1) by turning the two door locks that are located at the top and bottom right of the door. Use a hex key.

  1. Locate the "C shaped" retaining ring (4) that is located on the back side of the door (1) that holds the door pull (2) to the door (1). Refer to Illustration 2.

  1. Spread the "C shaped" ring (4) open. Remove the ring.

  1. Slide the door pull (2) straight outward from the front of the side door (1) .

Installation Procedure

  1. Open the cabinet door (1) and locate the hole near the middle of the door (1) on the right side.

  1. Retrieve the new door pull (2) and insert the door pull flat side first into the hole from the front of the door (1) .

  1. Spread the "C shaped" retaining ring (4) and slip the ring over the door pull from the back side of the door (1) .

  1. Seat the door pull (2) firmly against the door (1) so that a groove is visible all the way around the cylinder.

  1. Release the spreader so that the "C shaped" ring (4) firmly seats in the groove.

Caterpillar Information System:

UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Door
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies General Information (Cabinet Hardware)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys External Source Sync PWA (4 Wire Transformer Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Fan (4 Wire Transformer Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys UPS View Commands and Hot Keys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Flywheel Messages
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Graphical User Interface Messages
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys UPS Messages
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Flywheel Operating Parameters
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Current Transformers (Primary, Secondary)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System Voltage - Calibrate
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Transformer (T12 to T16 )
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Door Latch
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System Output Current - Calibrate
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys General Information (Maintenance Bypass Cabinet)
2006/05/22 New Cylinder Head Groups are Used {1100}
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Field Coil Current - Calibrate
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Telemetry - Calibrate
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Internal Component Preremoval Steps (Maintenance Bypass Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys System Fuse (Maintenance Bypass Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Bypass Pushbutton
C4.4 Industrial Engine Gear Group - Inspect
UPS Firmware Enhancement for Monitoring Bearing Serviceability{4480, 7551, 7620} UPS Firmware Enhancement for Monitoring Bearing Serviceability{4480, 7551, 7620}
C4.4 Industrial Engine Flywheel - Inspect
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.