Specifications
UPS 1200 Specifications
Technical Data
Show/hide table
Maximum kVA     | 1200     |
Maximum ekW     | 960     |
Input voltage     | 480     |
Output voltage     | 480     |
AC output current nominal amps     | 1445     |
System efficiency     | 97 per cent     |
AC Input Current     | |
Nominal Amps     | 1205     |
Maximum amps incl. recharge     | 1600     |
Specifications
Show/hide table
INPUT     | |
Voltage     | 480 vac 3 phase, 3-wire plus ground (from grounded wye source)     |
Voltage Range     | +10 percent to -15 percent (programmable)     |
Frequency     | 60Hz     |
Power Factor     | 0.99 at rated load and nominal voltage     |
Show/hide table
Harmonic Current Distortion     | |
Linear load     | less than 3 percent at 100 percent resistive load     |
Non-linear load     | less than 8 percent with 100 percent non-linear load     |
Surge Withstand     | Meets IEEE 587 and ANSI C62.41     |
Walk-in     | 1 to 15 seconds (programmable)     |
Bypass Source     | Same as input source - Synchronized frequency, phase, and voltage     |
Bypass Voltage Window     | +/- 10 percent (programmable within range)     |
Show/hide table
Output     | |
Voltage     | 480 vac, 3 phase, 3-wire plus ground     |
Show/hide table
Voltage Regulation     | |
Steady-state     | +/- 1percent of nominal for +/- 10 percent input and balanced or unbalanced load 0.8 lag to .9 lead pf, 7percent at –15 percent input voltage     |
Transient     | +/- 5 percent of nominal for 100 percent load step, or loss/ return of input     |
Recovery Time     | 50 millisecond maximum     |
Bypass Trigger     | Programmable up to +/-10 percent     |
Show/hide table
Frequency Regulation     | |
Normal Operation     | Synchronized to input     |
Free Running     | 0.1 percent stability     |
Synch Window     | Adjustable over a range of at least 0.3 Hz to 3 Hz     |
Frequency Slew Rate     | Adjustable over a range of at least 0.2 Hz per second to 5 Hz per second     |
Load Power Factor     | 0.8 lag to 0.9 lead for specified regulation and rating. 0.4 lag to 0.7 lead with reduced regulation or load     |
Show/hide table
Voltage Unbalance & Distortion     | |
Balanced Load     | less than 1 percent voltage unbalance and less than 1° phase displacement     |
50percent Unbalanced Load     | less than 3 percent voltage unbalance and less than 3° phase displacement     |
Linear Load     | less than 3 percent THD less than 2 percent SHD     |
100 percent Non-Linear Voltage distortion in accordance with EN 50091-3     | less than 5 percent THD     |
Load Imbalance     | The UPS is capable of supporting any combination of unbalanced load that does not exceed the maximum phase currents and the total output limitations of the UPS     |
Show/hide table
Overload Capability (nominal line without bypass)     | |
Continuous     | 105 percent     |
1 Minute     | 125 percent     |
5 Seconds     | Up to 150 percent     |
Dimensions and Weights
Show/hide table
All Cabinets     | |
Depth     | 1016 mm (40 inch)     |
Cabinet height without DC bus     | 1981 mm (78 inch)     |
System height with DC bus     | 2139 mm (84.2 inch)     |
Individual Cabinets     | |
4-wire (option)     |     |
Width     | 1981 mm (78 inch)     |
Weight     | 3448 kg (7600 lb)     |
Maintenance Bypass (option)     | |
Width     | 533 mm (21 inch)     |
Weight     | 1134 kg (2500 lb)     |
Bottom Entry (option)     | |
Width     | 1067 mm (42 inch)     |
Weight     | 272 kg (600 lb)     |
Input/Output     | |
Width     | 1067 mm (42 inch)     |
Weight     | 1134 kg (2500 lb)     |
Static Switch     | |
Width     | 1067 mm (42 inch)     |
Weight     | 907 kg (2000 lb)     |
Control (Note: ships attached to Inverter Cabinet)     | |
Width     | 914 mm (36 inch)     |
Weight     | 907 kg (2000 lb)     |
Inverter (Note: ships attached to Control Cabinet)     | |
Width     | 1067 mm (42 inch)     |
Weight     | 771 kg (1700 lb)     |
Energy Storage/each – 2 per standard system minimum     | |
Width     | 1067 mm (42 inch)     |
Weight     | Weight 3,040 kg 6,700 lbs 3040 kg (6700lb)     |
Environmental
Show/hide table
Acoustical noise     | less than 77dBA at 1.524 m (5 ft)     |
Temperature     |     |
Operating     | 0 °C (32 °F) to 40 °C (104 °F)     |
Storage     | −25 °C (−13°F) to 70 °C (158°F)     |
Humidity     | 5 percent to 95 percent (non-condensing)     |
Altitude     | Up to 914.4 m (3000 ft), (de-rate operating temperature range for higher elevation)     |
Emissions and Immunity     | FCC Class A, Subpart J of Part 15/ EN 50091-2     |
Safety
- UL 1778 Listed
- CUL CAN/CSA 22.2 No. 107.1 Listed
Ride Through Times (Sec)
Show/hide table
Number of Energy Storage Cabinets     | 100 percent load     | 75 percent load     | 50 percent load     | 25 percent load     |
2     | 13.5     | 17     | 26     | 50     |
3     | 20     | 25     | 39     | 75     |
4     | 27     | 34     | 52     | 100     |
Caterpillar Information System:
G3408C and G3412C Engines Accumulator Pressure - Test
G3408C and G3412C Engines Accumulator
TA22-4WD Agricultural Transmission Plate Locations and Film Locations
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys General Information (4 Wire Transformer Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Front Panel Display (MMS System Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Thermal Switch Terminal Block
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys UPS Shutdown
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Terminal Block (ESS)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System Fuses (MMS System Cabinet)
C13 On-highway Engine Connecting Rod Bearing Journal
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Cable Landing (4 Wire Output Cabinet)
3044C Industrial Engine Fuel Shutoff
G3408C and G3412C Engines Accumulator
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Internal Component Preremoval Steps (4 Wire Transformer Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys 4 Wire Transformer
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies General Purpose Interface PWA (MMS System Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies EPO Reset Switch (MMS System Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Fan Monitor PWA (MMS System Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Parallel Cabinet Controller PWA
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Parallel Cabinet Interface PWA
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Power Distribution PWA (MMS System Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies AC Interface PWA (MMS System Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Flywheel Bearing - Replace
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Transfer to Bypass Mode (SMS)