Note: Cleanliness is an important factor. Before the disassembly procedure, the exterior of the component should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.
Note: Put identification marks on all lines, on all hoses, on all harness assemblies, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
- Remove guard (1).
Show/hide table
Illustration 2 g01266537 - Disconnect harness assembly (2).
Show/hide table
Illustration 3 g01266538 - Disconnect switches (3) and remove covers (4).
Show/hide table
Illustration 4 g01266541 - Remove screws (5).
- Remove cover (6).
Show/hide table
Illustration 5 g01266542 - Reposition cover (8) and disconnect harness assembly (7).
- Remove cover (8).
Show/hide table
Illustration 6 g01266543 - Remove knob (9), screws (11) and handle control (10).
Illustration 1 | g01266535 |
Note: Cleanliness is an important factor. Before assembly, all parts should be thoroughly cleaned in cleaning fluid. Allow the parts to air dry. Wiping cloths or rags should not be used to dry parts. Lint may be deposited on the parts which may cause later trouble. Inspect all parts. If any parts are worn or damaged, use new parts for replacement.
- Position handle control (10) and install screws (11) and knob (9).
Show/hide table
Illustration 8 g01266542 - Position cover (8) and connect harness assembly (7).
- Install cover (8).
Show/hide table
Illustration 9 g01266541 - Install cover (6).
- Install screws (5).
Show/hide table
Illustration 10 g01266538 - Connect switches (3) and install covers (4).
Show/hide table
Illustration 11 g01266537 - Connect harness assembly (2).
Show/hide table
Illustration 12 g01266535 - Install guard (1).
Illustration 7 | g01266543 |