Specifications
Show/hide table
50 Hz Units | 60 Hz Units | |||||
---|---|---|---|---|---|---|
UPS 250i | UPS 500 | UPS 750 | UPS 300 | UPS 600 | UPS 900 | |
Rating | 250 kVA
200 kW |
500 kVA
400 kW |
750 kVA
600 kW |
300 kVA
240 kW |
600 kVA
480 kW |
900 kVA
720 kW |
Input Voltage | 380 VAC
400 VAC 415 VAC |
380 VAC
400 VAC 415 VAC |
380 VAC
400 VAC 415 VAC |
480 VAC | 480 VAC | 480 VAC |
AC Input | ||||||
Nominal Amperage | 315 A
299 A 288 A |
631 A
599 A 578 A |
946 A
899 A 867 A |
297 A | 595 A | 892 A |
Maximum Amperage Non-continuous(1) | 440 A | 880 A | 1320 A | 440 A | 880 A | 1320 A |
Maximum Amperage Continuous | 400 A | 800 A | 1200 A | 400 A | 800 A | 1200 A |
AC Output | ||||||
Nominal Amperage | 380 A
361 A 348 A |
761 A
723 A 696 A |
1140 A
1084 A 1044 A |
361 A | 722 A | 1084 A |
Typical System Efficiency | ||||||
100 Percent load | 96 Percent | 96 Percent | 96 Percent | 97 Percent | 97 Percent | 97 Percent |
Specifications for Input | ||||||
Voltage | 380 VAC, 400 VAC, 415 VAC, 3 phase plus neutral and ground(2) | 380 VAC, 400 VAC, 415 VAC, 3 phase plus neutral and ground(2)(3) | 380 VAC, 400 VAC, 415 VAC, 3 phase plus neutral and ground(2)(3) | 480 VAC, 3 phase plus ground(2)(4) | 480 VAC, 3 phase plus ground(2)(4) | 480 VAC, 3 phase plus ground(2)(4) |
Voltage Range | +10 Percent / −15 Percent (2)(5) | +10 Percent / −15 Percent (2)(5) | +10 Percent / −15 Percent (2)(5) | +10 Percent / −15 Percent (5) | +10 Percent / −15 Percent (5) | +10 Percent / −15 Percent (5) |
Power Factor | 0.99 at rated load and nominal voltage | 0.99 at rated load and nominal voltage | 0.99 at rated load and nominal voltage | 0.99 at rated load and nominal voltage | 0.99 at rated load and nominal voltage | 0.99 at rated load and nominal voltage |
Harmonic Current Distortion | ||||||
Linear Load | <3 Percent max at 100 Percent resistive load | <3 Percent max at 100 Percent resistive load | <3 Percent max at 100 Percent resistive load | <3 Percent max at 100 Percent resistive load | <3 Percent max at 100 Percent resistive load | <3 Percent max at 100 Percent resistive load |
Nonlinear Load | <8 Percent with a 100 Percent nonlinear load | <8 Percent with a 100 Percent nonlinear load | <8 Percent with a 100 Percent nonlinear load | <8 Percent with a 100 Percent nonlinear load | <8 Percent with a 100 Percent nonlinear load | <8 Percent with a 100 Percent nonlinear load |
Input Frequency | 50 Hz ± 10 Percent max (5)(6) | 50 Hz ± 10 Percent max (5)(6) | 50 Hz ± 10 Percent max (5)(6) | 60 Hz ± 10 Percent max (5) | 60 Hz ± 10 Percent max (5) | 60 Hz ± 10 Percent max (5) |
Specifications for Surge | IEEE 587/ANSI C62.41 | IEEE 587/ANSI C62.41 | IEEE 587/ANSI C62.41 | IEEE 587/ANSI C62.41 | IEEE 587/ANSI C62.41 | IEEE 587/ANSI C62.41 |
Specifications for Output | ||||||
Voltage | 380 VAC, 400 VAC, 415 VAC, 3 phase plus neutral and ground | 380 VAC, 400 VAC, 415 VAC, 3 phase plus neutral and ground | 380 VAC, 400 VAC, 415 VAC, 3 phase plus neutral and ground | 480 VAC, 3 phase plus ground(7) | 480 VAC, 3 phase plus ground(7) | 480 VAC, 3 phase plus ground(7) |
Voltage Regulation | ||||||
Steady state | ± 2% of nominal for ± 10% input and balanced or unbalanced load | ± 2% of nominal for ± 10% input and balanced or unbalanced load | ± 2% of nominal for ± 10% input and balanced or unbalanced load | ± 2% of nominal for ± 10% input and balanced or unbalanced load | ± 2% of nominal for ± 10% input and balanced or unbalanced load | ± 2% of nominal for ± 10% input and balanced or unbalanced load |
Flywheel Mode | ± 2% of nominal for steady state balanced or unbalanced load | ± 2% of nominal for steady state balanced or unbalanced load | ± 2% of nominal for steady state balanced or unbalanced load | ± 2% of nominal for steady state balanced or unbalanced load | ± 2% of nominal for steady state balanced or unbalanced load | ± 2% of nominal for steady state balanced or unbalanced load |
Transient | ± 5% of nominal for 100% load(8) | ± 5% of nominal for 100% load(8) | ± 5% of nominal for 100% load(8) | ± 5% of nominal for 100% load(8) | ± 5% of nominal for 100% load(8) | ± 5% of nominal for 100% load(8) |
Voltage Distortion | <3% at Full Linear Load | <3% at Full Linear Load | <3% at Full Linear Load | <3% at Full Linear Load | <3% at Full Linear Load | <3% at Full Linear Load |
<5% at Full Nonlinear Load | <5% at Full Nonlinear Load | <5% at Full Nonlinear Load | <5% at Full Nonlinear Load | <5% at Full Nonlinear Load | <5% at Full Nonlinear Load | |
Output Frequency | 50 Hz ±3%(9)(10) | 50 Hz ±3%(9) (10) | 50 Hz ±3% (9)(10) | 60 Hz ±10% (9)(10) | 60 Hz ±10% (9)(10) | 60 Hz ±10% (9)(10) |
Show/hide table
(1) | Including flywheel recharge current |
(2) | from a grounded wye source |
(3) | Except ± 10 Percent max at 380 VAC |
(4) | 4-wire optional |
(5) | programmable |
(6) | Also Available with 60 Hz nominal voltage |
(7) | 4-wire with optional 4-wire input |
(8) | 4 milliseconds recovery time |
(9) | utility synchronized, normal operation |
(10) | nominal ± 0.2 Percent free running |
Show/hide table
480 V Systems | |
Percent Load | Ride-Through Time |
100 Percent | 13 seconds |
75 Percent | 17 seconds |
50 Percent | 25 seconds |
25 Percent | 50 seconds |
380/400/415 V Systems | |
Percent Load | Ride-Through Time |
100 Percent | 15 seconds |
75 Percent | 20 seconds |
50 Percent | 30 seconds |
25 Percent | 60 seconds |
Caterpillar Information System:
C13 On-highway Engine Engine Oil Pan
2007/04/09 Improved Battery Chargers For Gensets are Available {1406}
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies UPS Operating Parameters
C9 On-highway Engine Cylinder Head
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Changing Parameters
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Operating Parameters Menu
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies UPS View Commands and Hot Keys
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Troubleshooting
C4.4 Industrial Engine Glossary of Electronic Control Terms
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Telemetry Parameters
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System Messages
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies MMU Master Messages
Procedure for Operating Caterpillar Filter Carts {0680, 0768, 5050} Procedure for Operating Caterpillar Filter Carts {0680, 0768, 5050}
2006/05/15 A New Air Lines Group is Used {1071}
336E Excavator Machine System Specifications Sprocket
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Load Cell - Calibrate
C13 On-highway Engine Cylinder Block
3044C Industrial Engine Product Lifting
C15 On-Highway Engine Fuel Temperature Sensor - Remove and Install
C15 On-Highway Engine Camshaft Position Sensor - Remove and Install
C15 On-Highway Engine Crankshaft Position Sensor - Remove and Install
TA19-M2WD and TA19-M4WD Agricultural Transmissions Clutch (Front Wheel Assist) - Remove
3500B Industrial Engines with the ADEM 3 Electronic Control Module Prelubrication System
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Hardware Revision - Version 3.0 Design