UPS View Commands and Hot Keys
Show/hide table
UPS Command Table | ||
---|---|---|
Name | Hotkey | Password Level |
Enable Printing of Startup Errors | \ | None |
Silence Display Buzzer | B | None |
Change Display Owner to MMU 1 | Alt-1 | None |
Change Display Owner to MMU 2 | Alt-2 | None |
Change Redundant MMU | Alt-B | Service |
Send Sys Cal Factors | Alt-C | Service |
Change Display Owner to this MMU | Alt-D | None |
Ethernet Loopback Test | Alt-E | None |
Force Op Params | Alt-F | Service |
Report AVR Demand FPGA Reading | Alt-G | None |
EPO Switch Status | Alt-I | None |
Show Ethernet Statistics | Alt-J | None |
Synchronize Event Logs | Alt-L | None |
Dump MMU Status Registers | Alt-M | None |
Toggle Debug Messages | Alt-N | Service |
Toggle Op Params Sent Over Can | Alt-O | Service |
Cancel Paging | Alt-P | Service |
Enter Regulation Only Mode | Alt-R | Service |
Enter AVR Spin Down Mode | Alt-S | Service |
Show Telemetry and Status Registers | Alt-T | None |
Show B-N (or Ground) Voltage | Alt-U | None |
Verify PCC Configuration | Alt-V | Service |
Toggle Discharge Walk in to Input VAC | Alt-W | Service |
Report Op Params that are not defaults | Alt-Z | None |
Start Genset | Control-[ | Service |
Show Bypass Status | Control-\ | None |
Stop Genset | Control-] | Service |
Send Op Params | Control-_ | None |
Send Tile Definitions | Control-A | None |
Enter Bypass Mode | Control-B | Service |
Resend Cal Prompt | Control-C | Service |
Download Event Log | Control-D | None |
Get Password Seed and Serial Number | Control-F | None |
Dump IGBT Currents | Control-G | None |
Show Hotkeys | Control-H | None |
Load default 60 Hz Op Params to Flash | Control-I | Service |
Show Diagnostic data | Control-J | Service |
Toggle Discharge Disable | Control-L | Service |
Show Revision Information | Control-N | None |
Enter Online Mode | Control-O | Service |
Clear View Password | Control-P | Service |
Reset Modem NVRAM to Default | Control-Q | Service |
Reset the Processor | Control-R | Service |
Enter Bypass Spin Down Mode | Control-S | Service |
Toggle Vacuum Level Checking | Control-V | Service |
Toggle Modem On/Off Hook | Control-W | None |
Brake the Rotor | Control-X | Service |
Report Modem Configuration | Control-Y | None |
Dump Setpoints | Control-Z | Service |
Download Binary Event Log | Menu Only | None |
Generate Test Alarm | Menu Only | Service |
Generate Test Notice | Menu Only | Service |
Load Default 50Hz Op Params to Flash | Menu Only | Service |
Load Restricted default params to Flash | Menu Only | Service |
Set Bearing Install Date to Current Time | Menu Only | Service |
Caterpillar Information System:
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Troubleshooting
C4.4 Industrial Engine Glossary of Electronic Control Terms
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Telemetry Parameters
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System Messages
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies MMU Master Messages
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies MMU Messages
C13 and C15 On-Highway Engines Monitoring System - Dash Lamps and Controls for the Aftertreatment Regeneration Device (ARD)
C4.4 Industrial Engine Power Sources
C13 Engine Engine Oil Pressure Sensor - Remove and Install - Intake Valve Actuator
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Service Connections
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Additional UPS Concepts
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Front Panel Overview
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Operating Parameters Menu
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Changing Parameters
C9 On-highway Engine Cylinder Head
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies UPS Operating Parameters
2007/04/09 Improved Battery Chargers For Gensets are Available {1406}
C13 On-highway Engine Engine Oil Pan
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Specifications
Procedure for Operating Caterpillar Filter Carts {0680, 0768, 5050} Procedure for Operating Caterpillar Filter Carts {0680, 0768, 5050}
2006/05/15 A New Air Lines Group is Used {1071}
336E Excavator Machine System Specifications Sprocket
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Flywheel Load Cell - Calibrate
C13 On-highway Engine Cylinder Block