C13, C15, and C18 Tier 4 Final Engines Caterpillar


Engine Oil Filter Base

Usage:

826K 232


图 1g01521184
发动机机油滤清器座

(1) 空心螺柱的扭矩 ... 68 ± 7 N·m (50 ± 5 lb ft)

(2) 滤清器座双头螺栓的扭矩 ... 68 ± 7 N·m (50 ± 5 lb ft)



图 2g01521185
剖面 A-A

(D) 将 154-9731 螺纹锁固胶涂抹到空心螺柱以下长度的螺纹上。 ... 10.5 ± 1.5 mm (0.41 ± 0.06 in)



图 3g01367915
剖面 B-B


图 4g01521183
剖面 C-C

(3)组装前,将 6V-6640 密封胶涂敷在杯形塞的孔上。

Caterpillar Information System:

100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC Operation Is Erratic
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Engine Does Not Shutdown (for EUI Engines)
C3.3 Industrial Engine Cylinder Head
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Service Tools
C15 and C18 Industrial Engines Air Shutoff Solenoid
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Starting Motor Remains Engaged (for EUI and PEEC Engines)
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Fault Identification
C3.3 Industrial Engine Valve Mechanism Cover
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus General Information
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus System Communication Module (Customer)
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Customer Interface Module
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Relay Driver Module
C3.3 Industrial Engine Exhaust Manifold
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Display of Voltage or Current or Power Is Inaccurate
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Indicators of Alarm Module or Remote Annunciator Are Constantly Flashing
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus Troubleshooting Diagnostic Codes
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0100 - FMI 02
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0100 - FMI 03
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0100 - FMI 04
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0110 - FMI 03
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0110 - FMI 04
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0111 - FMI 03
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0168 - FMI 03
100-200 kW Tactical Quiet Generators (TQG) EMCP2 Plus GSC CID 0168 - FMI 04
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.