For any pump test, the pump flow at 690 kPa (100 psi) will be larger than the pump flow at 6900 kPa (1000 psi) if the pump is operating at the same rpm. The pump flow is measured in L/min (US gpm).
The difference between the pump flow of two operating pressures is the flow loss.
Note: The values in the examples are not set values for any specific pump or for any specific pump condition. For information about the pump flows, refer to the Service Manual module Specifications, RENR8697, " 824H Wheel Dozer, 825H Soil Compactor, and 826H Landfill Compactor Electrohydraulic System" for the pump flow of a new pump at 690 kPa (100 psi) and at 6900 kPa (1000 psi). The 824H Wheel Dozer and the 826H Landfill Compactor are equipped with a 184-3123 Vane Pump. The 825H Soil Compactor is equipped with a 184-3122 Vane Pump.
Method of determining flow loss     | |||
    | Pump flow at 690 kPa (100 psi)     |
||
-     | Pump flow at 6900 kPa (1000 psi)     |
||
    | Flow loss     |
Example of determining flow loss     | |||
    | 217.6 L/min (57.5 US gpm)     |
||
-     | 196.8 L/min (52.0 US gpm)     |
||
    | 20.8 L/min (5.5 US gpm)     |
Flow loss that is expressed as a percentage of pump flow is used as a measure of pump performance.
Method of determining percent of flow loss     | ||||
Flow loss (L/min or US gpm)     | X     | 100     | =     | % Loss     |
Flow at 690 kPa (100 psi)     |
Method of determining percent of flow loss     | ||||
20.8 L/min (5.5 US gpm)     |
X     | 100     | =     | 9.5% Loss     |
217.6 L/min (57.5 US gpm)     |
Machine Test
Install a flow meter. Run the engine at high idle. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the formula in Table 5.
-     | Flow at 690 kPa (100 psi)     |
×     | 100     | =     | % Loss     |
Flow at 6900 kPa (1000 psi) |
|||||
    | Flow at 690 kPa (100 psi)     |
Bench Test
If the test bench can be run at 6900 kPa (1000 psi) and at full pump rpm, use the formula in Table 5 to determine the percent of flow loss.
If the test bench cannot be run at 6900 kPa (1000 psi) or at full pump rpm, run the pump shaft at 1000 rpm. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the top portion of the formula in Table 6. For the bottom part of the formula, run the pump shaft at 2000 rpm. Measure the pump flow at 690 kPa (100 psi).
-     | Flow at 690 kPa (100 psi)     |
×     | 100     | =     | % Loss     |
Flow at 6900 kPa (1000 psi) |
|||||
    | Flow at 690 kPa (100 psi) and 2000 rpm     |
Reference: For more information about the implement pump, refer to the Service Manual module Specifications, RENR8697, " 824H Wheel Dozer, 825H Soil Compactor, and 826H Landfill Compactor Electrohydraulic System". The 824H Wheel Dozer and the 826H Landfill Compactor are equipped with a 184-3123 Vane Pump. The 825H Soil Compactor is equipped with a 184-3122 Vane Pump .