The 237-5130 Digital Multimeter Gp Features a Built-in Infrared Thermometer {0785}

Usage:

769C 01X
Caterpillar Products:
  • All



  • Illustration 1g01051930

    The 237-5130 Digital Multimeter Gp measures true root mean square (RMS) AC voltage, DC voltage, current, resistance, capacitance, frequency, duty cycle and temperature. This multimeter group also features a built-in infrared thermometer and a built-in laser pointer. The display is easily read. This multimeter group provides a low cost alternative to some other multimeters that are available.

    Table 1
    Specifications    
    Feature     Specification    
    Temperature Sensor     Type-K Thermocouple (included)    
    IR spectral response     6 to 16 µm    
    IR emissivity     0.95 fixed    
    IR distance ratio     8:1    
    Input impedance     >7.5 MOhms (VDC and VAC)    
    AC response     True RMS    
    ACV bandwidth     50 Hz to 1 kHz    
    Display     4,000 count backlit, liquid crystal    
    Overrange indication     "OL" is displayed    
    Auto power off     15 minutes (approximately)    
    Operating temperature     50 ° C to 0 ° C (122 ° F to 32 ° F)    
    Storage temperature     -20 ° C to 60 ° C (-4 ° F to 140 ° F)    
    Weight    
    342 g (0.754 lb)    
    Size     187 X 81 X 50 mm (7.4 X 3.2 X 2.0 inch) includes holster    

    Table 2
    Electrical Specifications    
    Function     Range     Resolution     Accuracy (1)    
    DC voltage     400 mV     0.1 mV     ±(0.3% reading + 2 digits)    
    4 V 0.001 V     ±(0.5% reading + 2 digits)    
    40 V 0.01 V     ±(0.5% reading + 2 digits)    
    400 V 0.1 V     ±(0.5% reading + 2 digits)    
    600 V 1 V     ±(0.8% reading + 3 digits)    
    AC voltage         50 Hz to 400 Hz     400 Hz to 1 kHz    
    400 mV 0.1 mV     ±(1.5% reading + 15 digits)     ±(2.5% reading + 15 digits)    
    4 V 0.001 V     ±(1.5% reading + 6 digits)     ±(2.5% reading + 8 digits)    
    40 V 0.01 V     ±(1.5% reading + 6 digits)     ±(2.5% reading + 8 digits)    
    400 V 0.! V     ±(1.5% reading + 6 digits)     ±(2.5% reading + 8 digits)    
    600 V 1 V     ±(1.8% reading + 6 digits)     ±(3% reading + 8 digits)    
    DC current     400 µA     0.1 µA     ±(1.5% reading + 3 digits)    
    4000 µA 1 µA     ±(1.5% reading + 3 digits)    
    40 mA 0.01 mA     ±(1.5% reading + 3 digits)    
    400 mA 0.1 mA     ±(1.5% reading + 3 digits)    
    4 A 0.001 A     ±(2.5% reading + 5 digits)    
    20 A 0.01 A     ±(2.5% reading + 5 digits)    
    AC current         50 Hz to 400 Hz     400 Hz to 1 kHz    
    400 µA 0.1 µA     ±(1.8% reading + 8 digits)     ±(3.0% reading + 7 digits)    
    4000 µA 1 µA     ±(1.8% reading + 8 digits)     ±(3.0% reading + 7 digits)    
    40 mA 0.01 mA     ±(1.8% reading + 8 digits)     ±(3.0% reading + 7 digits)    
    400 mA 0.1 mA     ±(1.8% reading + 8 digits)     ±(3.0% reading + 7 digits)    
    4 A 0.001 A     ±(3.0% reading + 8 digits)     ±(3.5% reading + 10 digits)    
    20 A 0.01 A     ±(3.0% reading + 8 digits)     ±(3.5% reading + 10 digits)    
    Resistance     400 Ohms     0.1 Ohms     ±(0.8% reading + 4 digits)    
    4 kOhms 0.001 kOhms     ±(0.8% reading + 2 digits)    
    40 kOhms 0.01 kOhms     ±(1.0% reading + 2 digits)    
    400 kOhms 0.1 kOhms     ±(1.0% reading + 2 digits)    
    4 MOhms 0.001 MOhms     ±(1.0% reading + 2 digits)    
    40 MOhms 0.01 MOhms     ±(3.0% reading + 5 digits)    
    Capacitance     40 nF     0.01 nF     ±(5.0% reading + 7 digits)    
    400 nF 0.1 nF     ±(3.0% reading + 5 digits)    
    4 µF 0.001 µF     ±(3.5% reading + 5 digits)    
    40 µF 0.01 µF     ±(3.5% reading + 5 digits)    
    100 µF 0.1 µF     ±(5.0% reading + 5 digits)    
    Frequency (2)     5.000 Hz     0.001 Hz     ±(1.5% reading + 5 digits)    
    50.00 Hz 0.01 Hz     ±(1.5% reading + 5 digits)    
    500.0 Hz 0.1 Hz     ±(1.2% reading + 2 digits)    
    5.000 kHz 0.001 kHz     ±(1.2% reading + 2 digits)    
    50.00 kHz 0.01 kHz     ±(1.2% reading + 2 digits)    
    500.0 kHz 0.1 kHz     ±(1.2% reading + 2 digits)    
    5.000 MHz 0.001 MHz     ±(1.5% reading + 4 digits)    
    10.00 MHz 0.01 MHz     ±(1.5% reading + 4 digits)    
    Duty cycle (3)     0.1 to 99.9%     0.1%     ±(1.2% reading + 2 digits)    
    Temperature (Type-K Thermo- couple)     -20° C to 750° C (-4° F to 1382° F)     1° C/1° F     ±(3.0% reading + 3 digits) (4)    
    Temperature (IR)     -20° C to 270° C (-4° F to 518° F)     1° C/1° F     ±2° reading or ±2° C, ±4° F    
    ( 1 ) Accuracy is stated at 18° to 28° C (65° to 83° F) and less that 75% RH. The accuracy specification consists of two elements. The % reading is the accuracy of the measurement circuit. The + digits is the accuracy of the analog to digital converter.
    ( 2 ) Sensitivity: 0.8 V RMS min @20% to 80% duty cycle and <100 kHz; 5 V RMS min @ 20% to 80% duty cycle and >100 kHz.
    ( 3 ) Pulse width is 100 µs - 100 ms; frequency is 5 Hz to 150 kHz.
    ( 4 ) Probe accuracy not included

    Table 3
    Service Parts for the 237-5130 Digital Multimeter Gp    
    Pt. No.     Description    
    237-5125     Fuse (20-AMPERE)    
    8Q-6668     Fuse (250-VOLT, 0.5-AMPERE)    
    1U-9534     Battery (9-VOLT)    
    212-2158     Test Lead Tool Group    
    Back to top