Reference: Service Magazine, SEPD0695, 11 August 2003, "New VIMS Version 10.4 Class of Onboard Software"
Reference: Service Magazine, SEPD0644, 08 August 2002, "The VIMSpc (2002A) is Now Available"
Reference: Service Magazine, SEPD0522, 01 May 2000, "The VIMSpc99 Version 1.1.7a Software Update Is Now Available"
Reference: Service Magazine, SEPD0514, 06 March 2000, "The VIMSpc99 Version 1.1.7 Software Update Is Now Available"
Reference: Service Magazine, SEPD0504, 10 January 2000, "The VIMSpc99 Version 1.1.5 Software Update Is Now Available"
Reference: Service Magazine, SEPD0489, 20 September 1999, "VIMSpc99 Now Available"
New Features
- Trend ID numbers have been added to the Trend Summary report
- Master database version numbering now incorporates release year as the first number for easier identification and tracking.
- Model additions for Kress and Elphinstone machines.
- Addition of a template for the loader analysis report, the template adds all loader cycles used to load a truck and then displays the truck ID, the material loaded, total tons loaded, and total fuel used.
Fixes
- Pressure for the steering accumulator on the 797 is now viewable in "Data logger" and "Snapshot" graphs
Known Issues
- VIMSpc"2003A" may need to be restarted after viewing "Real Time Parameters" before viewing Real Time Parameters on another piece of equipment.
- In the Cumulative report the "Estimated Total Fuel Used" and "Estimated Fuel Used Idling" are calculated values within VIMS and will not necessarily match the totals of the engine ECM.
- The VIMS Database Update may fail with Non- English Microsoft Windows installed.