Installation Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
- Install a new O-ring onto auxiliary water pump (2) and install auxiliary water pump (2) onto the engine.
Illustration 1 | g00810427 |
- Install two nuts (3) that secure auxiliary water pump (2) to the engine.
- Install the hoses onto auxiliary water pump (2) and tighten clamps (1) .
Illustration 2 | g00810423 |
- Open the drain valve for the sea water circuit.
- Connect the battery.
Note: Do not run the auxiliary water pump with the valve for the sea water in the closed position. The impeller blades of the auxiliary water pump will be damaged.