Alternator - Delco 21SI Caterpillar


Field Winding - Test

Usage:

980C 13B



Illustration 1g00720928

(1) Slip rings

(2) Rotor

(3) Rotor shaft

Field Winding Continuity Test

  1. Set the multimeter to the 200 ohm resistance scale. Measure the resistance between the slip rings (1) .

  1. The resistance between the slip rings (1) should be within the following values.

    Resistance of field winding at 27 °C (81 °F)

    9X-6796 Alternator Gp ... 1.7 to 1.8 Ohms
    9X-9096 Alternator Gp ... 1.7 to 1.8 Ohms
    121-4134 Alternator Gp ... 1.7 to 1.8 Ohms
    121-4135 Alternator Gp ... 1.7 to 1.8 Ohms
    113-1379 Alternator Gp ... 1.7 to 1.8 Ohms
    125-9597 Alternator Gp ... 1.7 to 1.8 Ohms
    107-7977 Alternator Gp ... 9.5 to 10.7Ohms
    132-2156 Alternator Gp ... 9.5 to 10.7Ohms

  1. Replace the rotor (2) if the measurement is incorrect.

Field Winding Ground Test

  1. Set the multimeter to the 20 M ohm resistance scale. Measure the resistance between one of the slip rings (1) and the rotor shaft (3) .

  1. The multimeter reading should be greater than 100 K Ohms(0.100 M Ohms).

  1. Replace the rotor, if the multimeter reading is low. Low resistance indicates undesired continuity between the field winding and the rotor shaft.

  1. Repeat steps 1 through 3 for the other slip ring (1) .