Table 1
M5X COMMUNICATION TROUBLESHOOTING    
Problem     Possible Explanation     Action Required    
CCM shows error codes E02 and E08 when receiving data from the PC and will not communicate.     1. There is a protocol error.
2. The data is not in ASCII format.
3. An incorrect checksum was sent.
4. Baud rate of the CCM and PC not matched.    
Correct the message being sent to the CCM    
RS-232 receive lights are not lighted, and the CCM will not communicate with the PC even though no error codes are appearing.     Hardware connection between the PC and CCM is corrupted or disconnected.     Using the CCM PC software, connect to the CCM and determine if the connection to the PC is valid.    
Cannot log into the CCM     Connection problem exists or using the wrong M5X protocol for logging in.     Use a read request (PID $F0 $12) to verify that the PC is available to communicate with the CCM. If a valid response is returned, proceed to log in as described in the Logging in section of this manual. If the password has been forgotten, call the CCM Help Desk.    
Cannot get data from the electronic controller.     1. The electronic controller specified is not available.
2. The logged in security level is not high enough to support the request.
3. The electronic controller does not support the PID.    
1. Verify that the electronic controller and the CCM are connected on the same data link.
2. Verify that the logged in security level is high enough to support the request.
3. Verify that the electronic controller supports the PID being requested.    
Multiple responses are being generated from a single electronic controller     Multiple electronic controllers have the same MID.     Program the engine number of the electronic controller. Refer to the CCM/Data Link Guidelines section and Programming the Engine Number section in this manual.    
An entire broadcast list is not returned.     1. The electronic controller specified is not available.
2. The electronic controller does not support any one of the PID's.
3. The PID contains greater than two bytes of data.    
Refer to the CCM Customized System section, IID 10 and IID 13 in this manual    
A broadcast list update rate is too slow or inconsistent.     1. Too many parameters are being requested.
2. RS-232 baud rate is slow.    
1. Verify that the RS-232 and modem baud rates are at least 9600 baud. CCM can not broadcast more than 40 parameters per second. Use IID 13, Byte 7 to slow the update rate for stable parameters such as hour meter, atmospheric pressure, temperature, diagnostics, etc. Use a faster rate for more dynamic parameters such as engine speed, oil pressure, etc. Refer to the RS-232 Communication Protocol for Customized Systems section in this manual for further information.
2. Increase the RS-232 baud rate.    

Caterpillar Information System:

Customer Communication Module (CCM) for Diesel Engines Diagnostic Code - Troubleshoot
2000/01/01 Disassembly And Assembly Of Main Bearings For Journals Without Oil Holes {1203}
3408E and 3412E Engines for Caterpillar Built Machines CID 0190 FMI 08 Engine Speed signal abnormal
3408E and 3412E Engines for Caterpillar Built Machines CID 0190 FMI 07 Primary Speed Sensor misinstalled
723PLUS Digital Speed Control Electrostatic Discharge Awareness
3456 Engine, 836G Landfill Compactor, 834G Wheel Dozer and 988G Wheel Loader CID 0190 FMI 02 Loss of Engine Speed Signal
3516B Generator Set Engines with Dynamic Gas Blending Electrical System Operation
3500B and 3500B High Displacement Generator Set Engines Camshaft
3500B and 3500B High Displacement Generator Set Engines Crankshaft
3126B and 3126E On-highway Engines Camshaft - Install
3408E and 3412E Engines for Caterpillar Built Machines CID 0190 FMI 03 Engine Speed open/short to + batt
Uninterruptible Power Supply (UPS) 250 Fuse - Remove and Install
Customer Communication Module (CCM) for Diesel Engines System - Troubleshoot
3512B Petroleum Engines General Information (Electronic Control System)
723PLUS Digital Speed Control Installation
3456 Engine, 836G Landfill Compactor, 834G Wheel Dozer and 988G Wheel Loader CID 0262 FMI 03 5 Volt Sensor DC Power Supply short to +batt
C-10, C-12, C-15 and C-16 Industrial Engines CID 0263 FMI 03 Digital Sensor Supply short to +batt
UPS 250, UPS 300, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supply Utility Inverter Module - Remove and Install
3500B and 3500B High Displacement Generator Set Engines Engine Speed/Timing Sensor - Remove and Install
2000/01/31 Interactive Self-Paced Computer Training Course Available forTechnical Marketing Information (TMI) System Users {0314}
3456 Engine, 836G Landfill Compactor, 834G Wheel Dozer and 988G Wheel Loader CID 0262 FMI 04 5 Volt Sensor DC Power Supply short to ground
C-10, C-12, C-15 and C-16 Industrial Engines CID 0263 FMI 04 Digital Sensor Supply short to ground
G3412C, G3508, G3512, G3516, G3606, G3608, G3612 and G3616 Engines Customer Communication Module Diagnostic Code - Troubleshoot
G3412C, G3508, G3512, G3516, G3606, G3608, G3612 and G3616 Engines Customer Communication Module System - Troubleshoot
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.