113-1726 Metering Pump with Crossovers
Illustration 1 | g00513774 |
(1) Pin. (2) Gerotor. (3) Drive. (4) Bolts. (5) High capacity cylinder relief valve. (6) Anticavitation valve. (7) Plug for the check valve for the manual steering. |
The pin (1) in the body must be aligned with gerotor (2) and drive (3) .
(4) Tighten the bolts in the sequence that is shown. Torque for the seven bolts ... 14.1 ± 2.8 N·m (10.4 ± 2.1 lb ft)
(4) Final torque for the seven bolts ... 28.2 ± 2.8 N·m (20.8 ± 2.1 lb ft)
(5) Setting for the high capacity cylinder relief valve ... 27200 kPa (3945 psi)
(7) Torque for plug (7) ... 11.3 N·m (8.3 lb ft)
(7) The plug must be flush with the mounting surface or below the mounting surface.
119-8768 Metering Pump
Illustration 2 | g00513840 |
(1) Pin. (2) Gerotor. (3) Drive. (4) Bolts. (5) Plug for the check valve for the manual steering. |
The pin (1) in the body must be aligned with gerotor (2) and drive (3) .
(4) Tighten the bolts in the sequence that is shown. Torque for the seven bolts ... 14 ± 3 N·m (10.3 ± 2.2 lb ft)
(4) Final torque for the seven bolts ... 28 ± 3 N·m (20.7 ± 2.2 lb ft)
(5) Torque for the plug ... 11 ± 2 N·m (8.1 ± 1.45 lb ft)
(5) The plug must be flush with the mounting surface or below the mounting surface.