Note: Cleanliness is an important factor. Before assembly, thoroughly clean all parts in cleaning fluid. Allow the parts to air dry. Do not use wiping cloths or rags to dry parts. Lint may be deposited on the parts which may cause trouble. Inspect all parts. If any parts are worn or damaged, use new parts for replacement. Dirt and other contaminants can damage the precision component. Perform assembly procedures on a clean work surface. Keep components covered and protected at all times.
- Install poppet (13), spring (11), retainer (12), and retainer ring (10) in spool assembly (8).
- Install spacers (14).
Show/hide table
Illustration 2 g00953885 Show/hide tableImproper assembly of parts that are spring loaded can cause bodily injury.
To prevent possible injury, follow the established assembly procedure and wear protective equipment.
- Install spool assembly (8) and spring (9).
- Install O-ring seals (4) and (6). Install covers (3) and (7).
- Install flange assembly (5).
Show/hide table
Illustration 3 g00953884 - Install O-ring seals (2) on valve (1).
Illustration 1 | g00953887 |
Improper assembly of parts that are spring loaded can cause bodily injury. To prevent possible injury, follow the established assembly procedure and wear protective equipment. |
End By:
- Install the torque converter outlet relief valve. Refer to Disassembly and Assembly, "Torque Converter Outlet Relief Valve - Install".