This service program code is available with the 9.6X class of source software or later.
The event - configure (ESET) command allows the service technician to modify a configuration with the Information System Builder software program in order to turn off the functions that are listed here:
- Event Storage
- Event Display
- Service Lamp
- Broadcast (Radio Telemetry System)
Note: The "Event - Configure" command is not available for all events. The parameter must be designated as user configured in the configuration software.
Security
- The service program code only functions while the service tool (VIMS-PC) is connected.
- After the service tool (VIMS-PC) is disconnected for 30 seconds, this service program code will no longer be active.
Note: This command can only be viewed when VIMS-PC is not connected.
Setup
- Connect the service tool to the machine and establish communications with VIMS-PC.
- The message center should be in the background mode. background mode displays the following items on the message center: time, date, service hours and odometer reading (9.3X or later class of on board software). Use the keypad to enter the command "ESET" (3738). Then press the "OK" key. The message center will show the following message:
Show/hide table
Illustration 1 g00510982 - The service technician can select the desired "ESET" configured event by scrolling through the list of events. The service technician uses the "<" and ">" arrow keys on the keypad in order to scroll.
Note: The Master Event Number is a unique number that is assigned to an event. The "Master Event Number" is listed in the "Data Event Report" for a given configuration. The "Master Event Number" is viewed with the Information System Builder software application. This report can be generated by selecting the "data event report option" under the "Navigate Menu" of the Information System Builder software application. The numbers are listed in the "MST EVNT (Master Event)" column of the report.
Show/hide tableIllustration 2 g00511040 (1) Master event number
(2) Event Storage function
(3) Event display function
(4) Service lamp function
(5) Telemetry (broadcast) function
(6) Factory default function
(7) Status of the function
(8) Name of event - The service technician can select the desired function from the following list by pressing the corresponding "number" key. The "X" indicates that the function has been enabled. The "-" indicates that the function has been disabled.
The definitions of the functions are listed below:
Event Storage Function (2) toggles the status of the function from an "X" to a "-" in order to indicate that the function has been disabled (OFF).
The Event Display Function (3) toggles the status of the function from an "X" to a "-" in order to indicate that the function has been disabled (OFF).
Service Lamp Function (4) toggles the status of the function from an "X" to a "-" in order to indicate that the function has been disabled (OFF).
Telemetry (Broadcast)Function (5) toggles the status of the function from an "X" to a "-" in order to indicate that the Telemetry (Broadcast) function has been disabled (OFF).
"Factory Default" function (6) toggles the status of the function. The status is either an "X" or a "-". This is done in order to indicate that the "Factory Default" has been enabled (ON) or that the "Factory Default" has been disabled (OFF). See the Notes.
Note: All configurable events are set to the factory defaults that are designated in the configuration software until the default is changed by performing this procedure.
Note: The "ESET" command references the functions as the function has been setup in the configuration. The "ESET" command can turn OFF a function ONLY when the function is turned ON in the configuration software. The "ESET" command will NOT allow a function that is disabled from the factory in the configuration software to be turned ON.
Procedure
- To set the "EVENT DISPLAY" function, press the "2" key. The following message will be displayed on the message center.
Show/hide table
Illustration 3 g00511120 Show/hide tableIllustration 4 g00552273 - The ">" arrow key is used to toggle the status (“ON or OFF”) of the "EVENT DISPLAY". Press the "OK" key in order to accept the change. The message center will then display the current "Master Event Number message". Refer to illustration 4.
If the "X" is selected then the message center will display the event. If the "-" is selected the message center will NOT display the event.
- To set the "EVENT DISPLAY" function, press the "2" key. The following message will be displayed on the message center.
Use this procedure to modify the functions that are listed here: EVENT STORAGE, SERVICE LAMP and RADIO TELEMETRY SYSTEM (BROADCAST).