This service program code turns OFF the service indicator lamp for most active events (data or maintenance) that are presently shown on the display area.
Note: Not all active events can be acknowledged.
First, all of the active events must be turned OFF via the keypad. Enter the "EACK" command in order to show all the acknowledged events. Use the arrow keys in order to scroll through the event list. A "#" sign is located at the right of the display beside the warning category. The "#" sign indicates that the service indicator lamp is illuminated for the displayed event.
Illustration 1 | g00485490 |
The number 2 represents the category of event.
Use the keypad to enter "SVCLIT". Press the "OK" key in order to turn off the lamp. The "#" sign will disappear. The service indicator lamp will turn OFF after this procedure has been completed for ALL active events.
Illustration 2 | g00485491 |
With the 9.X and later classes of onboard software, the service indicator lamp will stay OFF under the following conditions:
- The key start switch is turned to the OFF position and then back to the ON position.
- Events that are associated with the reset procedure that are still active at the time that you turn the key start switch to the OFF position.
- Events that are still active when the key start switch is turned back to the ON position.
- There are no additional active events since the "SVCLIT" reset procedure.
With source software prior to 9.X, the service indicator lamp will turn ON again when the key start switch is turned to the OFF position and then back to the ON position. This is true provided that the "reset events" are still active.