Personal injury or death can result from a bucket falling. Keep personnel away from the front of the machine when lowering the bucket. |
Illustration 1 | g00396323 |
If the engine has been off for less than 10 minutes, move the control lever to the LOWER position.
Move the machine to level ground and to a location that is not in the work area.
If the engine has been off for more than 10 minutes and the engine is operable, start the engine. Move the control lever to the LOWER position.
If the engine has been off for more than 10 minutes and the engine is not operable, the following procedure is performed by one person.
Illustration 2 | g02745557 |
The bypass valve is located at the center of the machine.
If possible, straighten the machine and engage the steering frame lock link before you open the bypass valve.
The lift arms will start lowering when the bypass valve is opened.
Keep personnel away from the front of the machine.
Illustration 3 | g00398195 |
Slowly turn the square stem of the bypass valve in a clockwise direction. The square stem should be rotated 90 degrees.
The lift arms will lower to the ground.
Slowly turn the square stem of the bypass valve in a counterclockwise direction. The square stem should be rotated 90 degrees.