Illustration 1 | g00278181 |
NOTICE |
---|
If low impedance test equipment is used to test this switch, damage to the switch could result. Do not use a circuit tester light to test this switch. Do not use an analog multimeter to test this switch. Test only with a digital multimeter. |
(1) Torque for installing the switch ... 33 ± 4 N·m (24 ± 3 lb ft)
Note: During installation, the arrows must point toward the top of the tank.
(A) Switch contacts are closed.
(B) The switch contacts should be open when the hydraulic oil level decreases below 10 ± 5 mm (.4 ± .2 inch) from the centerline of the switch.
(C) The switch contacts should be closed when the hydraulic oil level rises to a minimum of 2.3 mm (.09 inch) from the bottom of the switch.
(D) Maximum travel distance equals 34.6 mm (1.36 inch).
(E) Switch contacts are open.