WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Caterpillar


TecJet 50 Flow Capacity

Usage:

The following graphs are based on the density of the gas at 0.82 kg/m3.

Please use the following equations to modify the graphs to your requirements:

Using the example of landfill gas (60% CH4 and 40% CO2)

Density = 1.221 kg/nm3

Gas temperature = 50 °C (max. = 65 °C)

Gas flow = 450 nm3/h

To correct the density and/or temperature:

Density = 1.221 * (273/(273+Tgas)) = 1.03 nm3/h

Flow = 450 * 1.221/1.03 = 532 nm3/h

Flow (at 0.82) = 532 * SQR(1.03/0.82) = 596 nm3/h

Maximum differential pressure (DP): 40 kPa

Minimum differential pressure: 3 kPa

Maximum absolute gas pressure (AP): 250 kPa


Figure 5-1. Flow Capacity for the TecJet 50, Version 1


Figure 5-2. Flow Capacity for the TecJet 50, Version 2


Figure 5-3. Flow Capacity for the TecJet 50, Version 3

Caterpillar Information System:

WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI TecJet 50 Specifications
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Messages
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Error Codes
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Introduction
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Replacement of the TecJet 50 Gas Control Valve
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Description of the TecJet 50 Menus
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Description of the TecJet 50 Monitoring Program
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Installation of the TecJet 50 Monitoring Software
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Configuration of the TecJet 50
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Pre-start Checks during Installation
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Installation of the TecJet 50
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Wiring Requirements
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Product Service Options
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Returning Equipment for Repair
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Replacement Parts
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI How to Contact Woodward
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Engineering Services
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Technical Assistance
WOODWARD TECJET 50 GAS CONTROL VALVE OPERATION AND CALIBRATI Declaration of Incorporation
CT11 and CT13 Truck Engines CT11 and CT13 Truck Engines
Driver Information Display (DID) Operating Instructions Driver Information Display (DID) Operating Instructions
Driver Information Display (DID) Quick Start Guide Driver Information Display (DID) Quick Start Guide
CT15 Truck Engine CT15 Truck Engine
Stereo Receiver Stereo Receiver
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.