Usage:
(1) 4N8150 Spring for bypass valves for oil cooler and oil filter:
Length under test force ... 2.175 in.(55.25 mm)
Test force ... 17.0 ± 1.3 lb.(76 ± 5 N)
Free length after test ... 3.69 in.(93.7 mm)
Outside diameter ... .81 in.(20.6 mm)
Filter and cooler bypass valves to open with a pressure difference of ... 37 ± 3 psi(255 ± 20 kPa)
(2) Torque for stud:
Put 9S3263 Thread Lock Compound on threads of the stud and tighten the stud to ... 60 ± 10 lb. ft.(80 ± 14 N·m)
(Engines With BrakeSaver)
The bypass valve for the oil filter opens with a pressure difference of ... 37 ± 3 psi(255 ± 20 kPa)
(1) 4N8150 Spring for bypass valves for oil filter:
Length under test force ... 2.175 in.(55.25 mm)
Test force ... 17.0 ± 1.3 lb.(76 ± 5 N)
Free length after test ... 3.69 in.(93.7 mm)
Outside diameter ... .81 in.(20.6 mm)
(2) Torque for stud:
Put 9S3263 Thread Lock Compound on threads of the stud and tighten the stud to ... 60 ± 10 lb. ft.(80 ± 14 N·m)