Usage:
Typical Example
8T9793
With a decrease in temperature, the switch must close at a minimum of ... 93°C (200°F)
With an increase in temperature, the switch must open at ... 107.2 ± 2.78°C (225 ± 37°F)
When installing torque to ... 100 ± 15 N·m (74 ± 11 lb ft)
8C3569
With a decrease in temperature, the switch must close at a minimum of ... 26.67°C (80°F)
With an increase in temperature, the switch must open at ... 37.78 ± 2.78°C (100 ± 37.004°F)
When installing torque to a maximum of ... 68 N·m (50 lb ft)
Typical Example
3E6451
With a decrease in temperature, the switch must close at a minimum of ... 93°C (200°F)
With an increase in temperature, the switch must open at ... 107 ± 3°C (225 ± 37°F)
When installing torque to ... 61 ± 7 N·m (45 ± 5 lb ft)
3E6449
With a decrease in temperature, the switch must close at a minimum of ... 27°C (80.6°F)
With an increase in temperature, the switch must open at ... 38 ± 3°C (100 ± 37.4°F)
When installing torque to ... 61 ± 7 N·m (45 ± 5 lb ft)
(1) Tighten to a torque of ... 20 ± 3 N·m (15 ± 2 lb ft)