Camshaft - Remove
Show/hide table
Required Tools | |||
Tool | Part Number | Part Description | Qty |
A | 1U-7638 | Magnetic Holding Tool | 12 |
B | 136-4632 | Timing Pin | 1 |
139-7063 | Timing Pin Adapter | 1 |
Start By:
- Remove the vibration damper and the pulley. Refer to Disassembly and Assembly, "Vibration Damper and Pulley - Remove and Install".
- Remove the rocker arms and the pushrods. Refer to Disassembly and Assembly, "Rocker Shaft and Pushrod - Remove".
- Remove the front cover. Refer to Disassembly and Assembly, "Front Cover - Remove".
Show/hide table
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Use Tooling (A) to reposition the valve lifters out of the way.
- Ensure that the No. 1 cylinder is at the top center compression stroke. Refer to Testing and Adjusting, "Finding Top Center Position for No. 1 Piston". Install Tooling (B) in the flywheel.
- Ensure that the timing marks on the following gears are aligned: the camshaft drive gear, the idler gear and the crankshaft gear.
Show/hide table
Illustration 2 g01125899 - Rotate camshaft gear (1) in order to access bolts (2). Remove bolts (2).
- Remove thrust plate (3).
- Remove camshaft (4) from the cylinder block.
Show/hide table
Illustration 1 | g01265762 |
Caterpillar Information System:
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Current Transformer (Static Switch Cabinet)
C280 Marine Auxiliary Engines System Configuration Parameters
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Zig Zag Transformer
C9 On-highway Engine Valve Actuator
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Zig Zag Overload Relay
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Zig Zag Circuit Breaker
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Snubber Assembly
G3600 Engines Aftercooler
Machine Start Switch Key May Not Fit Properly{1416} Machine Start Switch Key May Not Fit Properly{1416}
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Static Switch
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Universal Static Switch Interface PWA
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys System Fuse (Static Switch Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Internal Component Preremoval Steps (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Fuse (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Front Panel Display (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies General Purpose Interface PWA (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies EPO Reset Switch (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Power Distribution PWA (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies AC Interface PWA (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System I/O PWA (Flywheel Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies System I/O Daughter PWA (Flywheel Cabinet)
C280 Marine Auxiliary Engines Customer Parameters Worksheet
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys General Purpose Interface PWA (Static Switch Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys Fan (Static Switch Cabinet)