138-6875 Accumulator Charging Valve
Illustration 1 | g00734902 |
Cut-in pressure for charging the accumulator ... 11725 ± 345 kPa (1700 ± 50 psi)
Cut out pressure for charging the accumulator ... 14485 ± 345 kPa (2100 ± 50 psi)
Standby pressure at 7.2 L/min (1.90 US gpm) ... 2900 ± 140 kPa (420 ± 20 psi)
Relief valve pressure setting ... 16550 ± 690 kPa (2400± 100 psi)
Accumulator charge rate at 6900 kPa (1000 psi) ... 15.1 L/min (4.0 US gpm)
208-8650 Accumulator Charging Valve
Illustration 2 | g01305145 |
Cut-in pressure for charging the accumulator ... 11725 ± 345 kPa (1700 ± 50 psi)
Cut out pressure for charging the accumulator ... 14485 ± 345 kPa (2100 ± 50 psi)
Standby pressure at 7.2 L/min (1.90 US gpm) ... 4310 ± 210 kPa (625 ± 30 psi)
Relief valve pressure setting ... 16550 ± 690 kPa (2400± 100 psi)
Accumulator charge rate at 6900 kPa (1000 psi) ... 15.1 L/min (4.0 US gpm)