Usage:
(1) Torque for the bolts that hold the impeller to the rotating housing ... 20 ± 1 lb.ft.(2,8 ± 0,14 mkg)
(2) Clearance between the turbine and the housing:
Across the diameter ... .020 to .040 in.(0,51 to 1,02 mm)
Running ... .010 to .020 in.(0,25 to 0,51 mm)
Maximum permissible clearance:
Across the diameter ... .045 in.(1,14 mm)
Running ... .0225 in.(0,572 mm)
(3) Gap for the seal ring ... .005 to .015 in.(0,13 to 0,38 mm)
(4) Torque for the bolts that hold the stator to the carrier ... 20 ± 1 lb.ft.(2,8 ± 0,14 mkg)
(5) Torque for the bolt that holds the retainer to the shaft ... 81 ± 4 lb.ft.(11,2 ± 0,6 mkg)
(6) Torque for the bolts that hold the pilot to the housing ... 36 ± 2 lb.ft.(5,0 ± 0,3 mkg)
(7) Torque for the bolts that hold the drive gear for the oil pump to the impeller ... 20 ± 1 lb.ft.(2,8 ± 0,14 mkg)
(8) Clearance between the stator and the impeller:
Across the diameter ... .012 to .018 in.(0,30 to 0,46 mm)
Running ... .006 to .009 in.(0,15 to 0,23 mm)
Maximum permissible clearance:
Across the diameter ... .030 in.(0,76 mm)
Running ... .015 in.(0,38 mm)
(9) Clearance between the stator and the turbine:
Across the diameter ... .012 to .018 in.(0,30 to 0,46 mm)
Running ... .006 to .009 in.(0,15 to 0,23 mm)
Maximum permissible clearance:
Across the diameter ... .030 in.(0,76 mm)
Running ... .015 in.(0,38 mm)