Introduction
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.
Requirements
The following items are necessary to perform the VIMS 3G configuration:
PC Requirements
- Cat ET Version 2014C v1.0 or later
- VIMSpc 2015A or later, Order part number: FERV0066, Dealer subscription code: JERD-2138
- VIMSpc master database 15.2.9 or later
Refer to Special Instruction, REHS7337, ""VIMSpc" Update Release Information" for update instructions.
Equipment Requirements
The following items for equipment are required:
- 425-6889 Cable As ("VIMSpc")
COM 2 adapter or COM 3 adapter:
- 275-5121 Communication Adapter As (COM 2)
- 370-8059 Adapter Kit (Optional COM 2)
- 317-7485 Communication Adapter (COM 3)
Safety Section
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage. |
Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information. |
Do not perform any procedure in this Special Instruction until you have read this Special Instruction and you understand this information. Use only proper tools and observe all precautions that pertain to the use of those tools. The following procedures also should be observed.
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.
A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.
Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.
Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by Caterpillar is safe.
Ground the equipment. Improper grounding will result in electrical current paths that are uncontrolled and unreliable. Uncontrolled electrical circuit paths can result in damage to the equipment. Uncontrolled electrical circuit paths can also cause electrical activity that may degrade the electronics and communications. Ensure that all grounds are secure and free of corrosion.
Accidental engine starting can cause injury or death to personnel. To prevent accidental engine starting, turn the ignition switch to the OFF position and place a do not operate tag at the ignition switch location. |
Before starting this installation, in addition to the normal safety precautions taken whereas performing maintenance on heavy machinery, the following lockout/tagout procedure is recommended:
- Move the machine to a smooth, level location, and away from other working machines and personnel.
- Lower the implements to the ground.
- Stop the engine.
- Engage the parking brake for the machine.
- Place the disconnect switch in the OFF position.
Show/hide table
Illustration 1 g06276183 Lockout tags - Place a lockout tag on the disconnect switch.
Procedure
These instructions apply for VIMS 3G software releases with part number 562-7343 Monitor Software Gp or later.
"Internet Protocol" Screen
To change to the "Web Server Administrator Password" in the "Internet Protocol" screen, perform the following procedure:
- Connect to the machine with the COM adapter.
- Open Caterpillar Electronic Technician (Cat® ET).
Show/hide table
Illustration 2 g06342504 ECM selection screen - Select the "VIMS Main Module" ECM at the ECM selection screen and click the "OK" button. Refer to Illustration 2.
Show/hide table
Illustration 3 g06342507 Cat ET home screen - Wait until the screen is populated with the list of ECMs on the machine. Refer to Illustration 3.
Show/hide table
Illustration 4 g06342529 Configuration tool button - Click the Configuration Tool button. Refer to Illustration 4.
Show/hide table
Illustration 5 g06342530 "VIMS Main Module", "Internet Protocol" screen - Under the "VIMS Main Module" ECM, select the "Internet Protocol" heading. Refer to Illustration 5.
Show/hide table
Illustration 6 g06329670 Changing the "Web Server Administrator Password" - Open "Web Server Administrator Password" and change the default value to the new desired password. Refer to Illustration 6.
Show/hide table
Illustration 7 g06331058 "Change Parameter Value" screen - Click "OK". Refer to Illustration 7. A pop-up will appear asking to confirm the change.
Show/hide table
Illustration 8 g06333624 Confirmation for change pop-up - Click "Yes" to confirm the change. Refer to Illustration 8.
"Communicator" Tab
Perform the following procedure to access the "Communicator" tab:
- Connect the "VIMSpc" cable to the machine service port.
Show/hide table
Illustration 9 g06342870 VIMSpc application - Start the VIMSpc application on the PC. Refer to Illustration 9.
Show/hide table
Illustration 10 g06342871 "Connect" button - Use the "Connect" button to connect to the machine. Refer to Illustration 10.
- Select the "Status" button.
Show/hide table
Illustration 11 g06333634 "Communicator" tab - Select the "Communicator" tab. Refer to Illustration 11.
Show/hide table
Illustration 12 g06333650 - Click any sub menu item (except "Status"), for example "Auto File Download". Refer to Illustration 12.
Show/hide table
Illustration 13 g06333676 "Web Server Administrator Password" - Enter the "Web Server Administrator Password" and click "Apply". Refer to Illustration 13.
Show/hide table
Illustration 14 g06333707 "Auto File Download" screen Show/hide tableIllustration 15 g06333711 - "Login Successful" message will be shown on successful attempts. Refer to Illustration 14.
If entering a wrong password, a prompt will appear asking to check the password. Refer to Illustration 15.
Show/hide tableIllustration 16 g06333712 "Auto File Download" screen - Once you have logged in, you will be able to change settings. Click "Auto File Download". The "Auto File Download" screen will appear. Refer to Illustration 16.