279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System Caterpillar


MID 039 - CID 0681 - FMI 05

Usage:

256C DWS
Conditions Which Generate This Code:


Illustration 1g01283430

Schematic of the Parking Brake Solenoid Circuit

This diagnostic code is recorded when the ECM reads the current of the solenoid as being below normal.

The possible causes are listed:

  • The energize circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The ECM has failed. This is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore the created diagnostic codes. Clear these diagnostic codes when the original diagnostic code is corrected.

System Response:

CID 681 FMI 05 will generate a level 2 warning. The machine will be brought to a stop and the park brake will engage. The park brake will not release until the diagnostic has been corrected and the hystat lever has been brought back to the neutral position.

Test Step 1. CHECK THE SOLENOID

  1. Disconnect the solenoid from the machine harness.

  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire A958-WH) to contact 2 (wire H807-YL).

  1. Turn the key start switch to the ON position. Do not start the engine.

  1. Observe the status of the CID 0681 FMI 05 diagnostic code.

Expected Result:

The CID 0681 FMI 05 diagnostic code is no longer active. A CID 0681 FMI 06 diagnostic code becomes active when the jumper wire is connected.

Results:

  • YES - The CID 0681 FMI 05 diagnostic code is no longer active. A CID 0681 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.

    Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

  • NO - The CID 0681 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.

Test Step 2. CHECK THE CIRCUIT FOR AN OPEN

The jumper wire that was installed in the previous Test Step remains in place.

  1. Disconnect the negative battery cable and turn the key start switch to the OFF position.

  1. Disconnect the machine harness ECM connector J2 from the ECM.

  1. At the machine harness connector J2 for the ECM, measure the resistance from contact J2-2 (wire A958-WH) to contact J2-4 (wire H807-YL).

  1. While observing the multimeter resistance measurement, wiggle the machine harness connectors for the ECM and wiggle the machine harness connector for the solenoid. Gently pull on the wires and move the wires around.

Expected Result:

The resistance measurement is less than 5.0 ohms at all times during the manipulation of the harness and connectors.

Results:

  • OK - The resistance measurement is less than 5.0 ohms. The resistance measurement is not indicating an open or a bad connection in the circuit. Proceed to Test Step 3.

  • NOT OK - The resistance measurement is greater than 5.0 ohms. The resistance measurement is indicating and open circuit or a bad connection in the machine harness.

    Repair: A resistance measurement that is greater than 5000 ohms could indicate that a wire is either not connected or is open. A resistance measurement that is greater than 5.0 ohms but less than 5000 ohms could indicate that one of the connection points in the circuit is not open but is not a good connection.The open or possible bad connection is in supply wire A958-WH or in return wire H807-YL of the machine harness. Refer to the complete machine Electrical System Schematic. Check all of the connectors that are in the solenoid circuit. Ensure that all connections are clean, secure and in good condition. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK THE OPERATION OF THE ECM

The key start switch remains in the OFF position. The machine harness connector for the solenoid and the ECM J2 connector remains disconnected.

  1. Remove the jumper wire that was installed in the last test step.

  1. At the machine harness connector J2 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire A958-WH and socket at contact J2-2 from the harness connector.

  1. Reconnect the machine harness J2 connector to the ECM.

  1. Reconnect the negative battery cable and turn the key start switch to the ON position.

  1. Use a 7X-1710 Multimeter Probe that is not connected to a multimeter or a similar device to make contact with the ECM pin at J1-61 through the vacant space in the J2 connector.

  1. While observing the status of the active CID 0681 FMI 05 diagnostic code, ground the other end of the 7X-1710 Multimeter Probe to frame ground.

Expected Result:

The CID 0681 FMI 05 diagnostic code is no longer active. A CID 0681 FMI 06 diagnostic code becomes active when the ECM pin at J2-2 is grounded.

Results:

  • YES - The CID 0681 FMI 05 diagnostic code is no longer active. A CID 0681 FMI 06 diagnostic code has been activated after the ECM pin is grounded. The ECM has responded correctly to the grounded circuit condition in the solenoid circuit. The ECM is most likely not causing the problem.

    Reinstall the disconnected solenoid energize wire back into the correct spot in the ECM connector before proceeding to the next test step.

    Proceed to Test Step 4.

  • NO - The CID 0681 FMI 05 diagnostic code remains active. The status of the active diagnostic code does not change when the ECM pin for the solenoid is grounded.

    Repair: The ECM has not responded correctly to the grounded condition in the solenoid circuit. The operation of the ECM is not correct.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 4. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the sensor circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the CID 0681 FMI 05 diagnostic code.

Expected Result:

The CID 0681 FMI 05 diagnostic code is active.

Results:

  • YES - The CID 0681 FMI 05 diagnostic code is active. The diagnostic code has not been corrected.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.If the cause of the problem is not found in the machine harness, the ECM may have failed. This is unlikely as the ECM responded correctly to the grounded condition in the previous test step.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the active diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0681 FMI 05 diagnostic code is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

RM-500 Road Reclaimer/Soil Stabilizer Power Train Piston Motor (Propel)
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0681 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0600 - FMI 04
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0600 - FMI 03
938H and IT38H Wheel Loader and Integrated Tool Carrier Power Train Temperature Sensor (Transmission Oil)
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0490 - FMI 04
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0490 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0358 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0358 - FMI 05
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0358 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0357 - FMI 13
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0357 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0681 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1007 - FMI 02
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1007 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1007 - FMI 04
120M and 12M Motor Graders Hydraulic System Oil Level - Check
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1190 - FMI 04
RM-500 Road Reclaimer/Soil Stabilizer Power Train Flow Divider Valve
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1703 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1703 - FMI 05
RM-500 Road Reclaimer/Soil Stabilizer Machine Systems Steering Wheel - Remove and Install
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1703 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1703 - FMI 13
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.